KeLing Purification Technology Company

KeLing Purification Technology Company Limited ------------------------------------------------------------- Advanced. High-Qulity. Reasonable.

Manufacturer from China
Verified Supplier
12 Years
Home / Products / Laminar Flow Cabinets /

Photoelectric Laminar Flow Cabinets

Contact Now
KeLing Purification Technology Company
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MrsZhao
Contact Now

Photoelectric Laminar Flow Cabinets

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :K-LING
Certification :CE,
Model Number :KEL-HCB-2
MOQ :1SET
Price :NEGOATION
Packaging Details :PLOWOOD PACKING
Delivery Time :8 WORKING DAYS
Payment Terms :Ex works/FOB/CIF/ CNF
Supply Ability :500Sets/month
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

ISO5 Laminar AirFlow Cabinet Hood 220V/60HZ For Photoelectric Industry

Quicky Detail

External size: 1200x850x1580mm

Internal Size: 1180x600x650mm

The Cap Size : 1180x1000mm

curtain : PVC with plastic Curtain

Purification rank: Class100

ULPA filter efficiency:99.99995%@0.12um

ULPA filter size : 1170x610x69

Air speed :0.45m/s

Electric : 220V/60HZ

Introduction:

laminar airflow cabinet hood filtered air is passed through the main chamber of the flow bench in a vertical laminar air stream before being of the clean bench, it is designed for larger –scale process protection in industry application typically requiring multiple units connected in an assembly line configuration, usually it is placed within an ISO class8 clean room to provide an ultra-clean environment directly at the process level.

Applications:

clean rooms, electronics assembly, semiconductors, pharmaceutical .aerospace and medical devices industries, mycology and food microbiology, plant and mammalian Cell culture, applications benefiting from the isolated work surface frames design which virtually eliminates vibration.

Operating features:

1: It is manufactured for the most demanding clean room applications, offering a combination of value,

high quality construction.

2: LED control board with CE remark, low operating noise levels

3: Stainless steel or antimicrobial coating on all painted surfaces minimizes contamination.

Long –life ULPA air filter for supply air flow.

4: Horizontal air laminar flow cabinet/laboratory clean hood adopts wind volume adjustable fan system,
light-touch type switch and dual-speed voltage regulation device to keep wind speed in working area
in ideal state.
5: Horizontal air laminar flow cabinet/laboratory clean hood adopts super thin type aluminum-frame
clapboard-free high-efficiency air filter which reduces static-pressure tank to the smallest size,
thus to reduce the size of outer case.
6: Horizontal air laminar flow cabinet/laboratory clean hood is the newest type bench in present market.
The front cover may be opened directly for exchanging filter, electr

7: American Dwyer pressure remind of you replace the ULPA Air filter in regular.

Photoelectric Laminar Flow Cabinets

Illustration:

6: Pre-Filter 7 : Fans 1: Control board 3: ULPA air filter 2: lamp 5: Socket 4: Glass 8: wheel 9: Leg

Technical Parameter

MODEL

KEL-HCB-2

External size (mm)

(WXDXH)

1200x850x1580mm

Work zone (mm)

(WXDXH)

1180x600x650mm

Purification rank

FS209E 100Rank

Display

LED Digital Display

Rating airflow(m3/h)

1200m3/h

Filtration efficiency

More than 99.99%@0.3um H13-H14

Average wind speed

0.3-0.6m/s

Intensity of illumination

>300Lux

Fluorescent lamp

20Wx1

Material

(Option)

1:Entirety Sus201/304.

2: External is steel with power coated, Internal is SUS304

3: External is steel with power coated. Internal is SUS201

Base stand material

Adopting cold-roll steel plate with corrosion-proof coating

Power

280w

Noise

<65dB

Electrical

AC 110V-240V / 50-60HZ

Net weight

230kgs

Gross weight

270kgs

Packing size

1200x800x1750 mm

Customers design is available.

Factory test:

All of equipment is individually factory tested for safety and performance in accordance with international Standards. Each unit is shipped with a documentation outlining the tests undertaken and the units individual results for each unit.

Factory test include:

-- functional test and visual inspection

-- electrical safety tests

-- air velocity testing

-- purification rank test (if need)

Warranty:

Our equipment is warranty for 1 year excluding consumable parts and accessories.

All equipment is shipped with a comprehensive use’s manual complete with a report documenting all test procedures.

Additional IO/OQ/GMP document is available upon request.

Contact our sales representative for specific warranty details or document request.

Consumable parts illustration:

1: Pre-filter: each one should be replacement in each 6 month, but it can refresh no more three times.

2: HEPA filter: each one should be replacement in each half and one years.

Why you choose K-LING Company ?

Professional sales:

• We value every inquiry that you sent to us, ensure quick competitive offer.

• We cooperate with customer to bid tenders. Provide all necessory docuement.

• We are a sales team, with all techinical support from engineer team

Punctual delivery time:

• Production / inspection report provide before shipment

• Shipping notice or insurance for you when your goods is shipped.

After sales service:

• We respect your feed back after receive the goods.

• We provide one year warranty after goods arrive.

• We promise all spare parts available in lifetime use.

• We care of your complain within 48hours.

Payment Term:

T/T in advance, 30% before place the order, 70% when you see copy BL

Or 30% T/T in advance before place the order, 70% LC at sight.

Photoelectric Laminar Flow Cabinets

Photoelectric Laminar Flow Cabinets

Photoelectric Laminar Flow Cabinets

Inquiry Cart 0