Fireproof Sandwich Panels Clean Booth, Laminar Flow Down Booth
Introduction
The airflow in a modular cleanroom is a very important factor in the overall performance of the cleanroom. Most cleanrooms have an average air velocity of between 0.25-0.5 m/s. This is a relatively low air velocity, and therefore has the potential to be interrupted or disturbed by people and/or machinery within the cleanroom. On the other hand, raising the air speed too high will increase operational costs. When deciding upon the air speed to set within a cleanroom, an enterprise must first confirm that the selected air speed will be able to maintain an environment that meets cleanliness standards. However, the air speed required to meet these requirements should not be exceeded by too much, otherwise you will incur unnecessary costs.
Besides determining the appropriate air velocity, steps must be taken to maintain a constant airflow and velocity. Otherwise, it is possible for air to build up around the walls and form a sort of vortex. If this occurs it is extremely difficult to cycle the air in and out of the room, and thus nearly impossible to maintain a clean environment.
In order for a laminar airflow cleanroom to maintain constant, uniform airflow, all fans must be set to the same speed. Additionally, if the air speed falls outside of the 0.25-0.5 m/s range, it is also possible for vortex-like air patterns to occur in the cleanroom.
Features:
(1) Assembly structure designed, easy installation and easily moved
(2) Directional wheels can be installed, suitable for small building and high cleanliness area;
(3) Modular design: clean booth can be as small as several square meters and can be as large as hundreds of square meters
(4) It has large useful and effective area; while compared with traditional clean room, it has such features like low investment, high return and stable.
Structure
Following options are available
1. Pass box
2. Air shower
3. ULPA filter
4. Sticky mats
5. Barometer
6. Gowning area
7. Pressure different control device
8. Transparent/grid PVC curtain
9. Thermo-static and humid-static air conditioning system.
When start the clean room
What information do you need to provide us for design the cleanbooth
1.What industry do you need the cleanbooth
2.What size and height and cleanliness do you need for cleanbooth?
3.What kind of work will be do in cleanbooth?
4.What kind of material for wall you want?
5.Do you have another special requirment?
Dimensions:
Class | Model | Dimension (WxDxH)mm *inner height | FFU Q'ty | Airflow (m3/h) |
Class 10-100 | MCR4X4 | 1220X1220X2150 | 2 | 2300 |
Class 10-100 | MCR4X8 | 1220X2440X2150 | 4 | 4600 |
Class 10-100 | MCR8X8 | 2440X2440X2150 | 8 | 9200 |
Class 10-100 | MCR8X12 | 2440X3660X2150 | 12 | 13800 |
Class 10-100 | MCR8X16 | 2440X4880X2150 | 16 | 18400 |
Class 10-100 | MCR8X20 | 2440X6100X2150 | 20 | 23000 |
Class 10-100 | MCR12X12 | 3660X3660X2150 | 18 | 20700 |
Class 1000 | MCR8X12 | 2440X3660X2150 | 9 | 10350 |
Class 1000 | MCR8X16 | 2440X4880X2150 | 12 | 13800 |
Class 1000 | MCR8X20 | 2440X6100X2150 | 15 | 17250 |
Class 1000 | MCR10X12 | 3050X3660X2150 | 8 | 9200 |
Class 1000 | MCR12X12 | 3660X3660X2150 | 10 | 11500 |
Class 1000 | MCR12X16 | 3660X4880X2150 | 12 | 13800 |
Class 1000 | MCR12X20 | 3660X6100X2150 | 16 | 18400 |
Class 10,000 | MCR8X8 | 2440X2440X2150 | 2 | 2300 |
Class 10,000 | MCR8X12 | 2440X3660X2150 | 2 | 2300 |
Class 10,000 | MCR8X16 | 2440X4880X2150 | 4 | 4600 |
Class 10,000 | MCR12X16 | 3660X4880X2150 | 5 | 5750 |
Other sizes as request.